БХТ
CONSTRUCTION DEVELOPMENT CENTER
Accredited testing laboratory · MNS ISO/IEC 17025 · TL1:9
Laboratory: Керамик эдэлхүүний лаборатори
MNAS
TL1:9
TL1:9
TEST REPORT
No. БХТ-2026-00001Date: 2026-09-24
| Sample code | LAB-2026-00001 | Sample received on | 2026-09-24 20:41 |
|---|---|---|---|
| Customer | Тест захиалагч (устгаж болно) | Reg. No. | Not specified |
| Sample name, quantity | Керамик тоосго, 10 pcs | Testing period | 2026-09-20 – 2026-09-24 |
| Standards applied | MNS 0138:2010, MNS 0982:1980, MNS 0983:1980, MNS 2915:1980 | ||
| Source / quarry | Not specified | Object address | Not specified |
| Appearance | Гэмтэлгүй, бүтэн | Environmental conditions | — |
| Conclusion | CONFORMS to requirements | ||
| No. | Test method | Parameter | Unit | Requirement | Result | Conclusion |
|---|---|---|---|---|---|---|
| 1 | MNS 0138:2010 | Хэмжээ, Уртад | mm | ±4 | 251 (nominal 250) | ✓ |
| 2 | MNS 0138:2010 | Хэмжээ, Өргөнд | mm | ±3 | 118 (nominal 120) | ✓ |
| 3 | MNS 0138:2010 | Хэмжээ, Зузаанд | mm | ±3 | 66 (nominal 65) | ✓ |
| 4 | MNS 0138:2010 | Тоосгоны жин | kg | - | 3.2 | — |
| 5 | MNS 0138:2010 | Чийг | % | - | 1.1 | — |
| 6 | MNS 2915:1980 | Дундаж нягт | kg/m³ | 1400-2000 | 1750 | ✓ |
| 7 | MNS 0982:1980 | Гулзайлтын бат бэх | MPa | ≥1.8 | 2.1 | ✓ |
| 8 | MNS 0982:1980 | Шахалтын бат бэх | MPa | ≥7.5 | 8.1 | ✓ |
| 9 | MNS 0983:1980 | Хүйтэн ус шингээлт | % | ≥6 | 7 | ✓ |
| 10 | MNS 0983:1980 | Халуун ус шингээлт | % | - | 12.5 | — |
| 11 | MNS 0138:2010 | Булангийн 15 мм-ээс их гүнтэй эмтрэлийн тоо | pcs | 2 | 2 | ✓ |
| 12 | MNS 0138:2010 | Булангийн 3мм-ээс 15 мм хүртэл гүнтэй эмтрэлийн тоо | pcs | 4 | 4 | ✓ |
| 13 | MNS 0138:2010 | Ирмэгийн 15 мм - ээс урт, 3 мм- ээс их гүнтэй эмтрэлийн тоо | pcs | 2 | 2 | ✓ |
| 14 | MNS 0138:2010 | Ирмэгийн 3мм- ээс 15мм хүртэл урттай, 3мм -ээс их гүнтэй эмтрэлийн тоо | pcs | 4 | 4 | ✓ |
| 15 | MNS 0138:2010 | Ан цавын тоо | pcs | 2 | 2 | ✓ |